Isol-8 SubStation

17.990kr35.440kr

  • Strømrens
  • DC-filtrering (alle modeller)
  • Transmodal filter (LC og HC)
  • Sort og sølv finish

NB! Kun tilgjengelig i Oslobutikken.

Produktnr: I/A Kategori:

Isol-8 SubStation

The SubStation LC, HC and Axis build on the substantial achievements of the Substation Vogue and Qube with a new semi modular format and DC blocking as standard. Standing alone or in combination for even greater performance; they form a flexible, effective solution to satisfy the most demanding audiophile.

Each unit provides a different function, so you can upgrade your power supply as your system evolves without costly trade-ins or compromising performance.

They all share the same outstanding UK made build quality with a five year guarantee. PTFE insulated silver plated wiring, premium quality components and connectors are standard. All versions have DC blocking, a custom earth line choke to suppress noise on the safety earth, and surge and spike protection for peace of mind. The substantial all alloy, non magnetic, half width case allows two units to be placed side by side on a standard equipment shelf.

ISOL-8-SUBSTATION


SubStation LC

The SubStation LC (Low current) is the foundation of the range, optimising power for your source components. 8 Amps is continuously available across the four outlets. Preceded by a high power DC blocking Axis circuit, each outlet has its own multistage Transmodal filter to suppress cross-contamination between components. The LC is constructed to last a lifetime with carefully auditioned premium components including OFC copper foil inductors. With the SubStation LC at heart of your system it will readily liberate performance lost to compromised mains power. It is our ultimate passive power conditioner for low to medium current loads.

ISOL-8-SUBSTATION-LC


SubStation HC

The SubStation HC (High current) complements the LC, providing 16 Amps continuously across its two outlets for high peak current loads such as amplification.  A high capacity DC blocking Axis circuit is complemented by a massively constructed Transmodal filter. Using proprietary custom wound components, kilos of OFC copper foil and premium capacitors to keep series resistance low, the SubStation HC effortlessly tackles the very thorny problem of effectively cleaning a high current power supply without compromising dynamic performance.ISOL-8-SUBSTATION-HC


SubStation Axis

The SubStation Axis provides a more economical third option with the considerable benefits of DC blocking, but without multistage filtering. Where the mains waveform is not perfectly symmetrical in energy content a DC component will be present, this partially saturates the power supply’s mains transformer. This can lead to acoustic hum and reduced performance from connected equipment.  A high current version of the acclaimed ISOL-8 Axis circuit blocks any DC on the incoming mains. Four outlets supply a continuous current capability of 16A across the unit with a suitable mains connection. The SubStation Axis is eminently suitable for lifting the performance of all high end system components.

ISOL-8-SUBSTATION-AXIS

FARGESort, Sølv

DC Blocking

DC on the Mains.

Power supplies in Hi-Fi and AV equipment often assume connection to a perfect mains supply. In theory the mains waveform should be pure AC: a perfect, symmetrical sine wave.

Many of the myriad appliances connected to the supply, at home and in industry; from electronic dimmers to computer power supplies, use the AC energy available in a mains cycle unevenly. The net result is the effective addition of DC to the mains network.

This effect is inevitable and also inherently unpredictable. In practice the waveform can arrive at the end-user clipped, distorted and asymmetric. Simplistic analyses of unmatched peak voltages are not the whole story: Any AC waveform which does not have equal energy in both positive and negative phases will contain a DC component; regardless of what the peak voltages are or what the wave shape is.

The AC transformers commonly found in audio equipment cannot, by nature, tolerate significant DC without being compromised.

As all transformers convert power through the medium of magnetism, any DC present will inhibit its capacity to transform AC by partially or completely saturating the magnetic circuit. It is this vulnerability to DC that causes acoustic hum and significantly reduces the transformer’s power capacity. Even measured at comparatively low levels we have found that this has a significant negative impact on the following power supply and circuit performance, which in turn can degrade sound quality.

The graph below is an illustration of an imperfect mains waveform before processing by the Axis circuit:

ISOL-8-SUBSTATION-AXIS

The ISOL-8 Axis circuit re-balances the energy axis of the mains waveform without restricting the effective current capacity. This eliminates any DC voltage on the mains power supply, suppressing acoustic hum and liberating system performance.

Waveform after processing by the Axis circuit:ISOL-8-SUBSTATION-AXIS

Transmodal technology (LC & HC)

Transmodal Technology

In order to understand ISOL-8 Transmodal technology, it is necessary to visit some basic fundamentals of filters in power applications. We have simplified the information below as far as possible for clarity.

When an electrical load is connected to a source a current loop is formed. Transfer of energy takes place as current flows from the source through the load and returns to the source. Electricity makes no distinction between mains power or performance degrading noise. It is all the same to any connected circuit.

 

Noise can enter any current loop in a number of ways, but can be largely categorised into two types or modes.

Firstly we’ll look at Differential Mode Noise. This occurs when only one conductor of a current loop encounters a noise source. The noise therefore circulates within the loop. For example this occurs when conductors are not closely coupled; such as in equipment internal wiring or when the noise is generated from circuit elements within the load or source itself.

 

ISOL-8-SUBSTATION-TRANS

Secondly we’ll look at Common Mode Noise. This occurs in both conductors of a current loop; equally and in phase with respect to ground. An instance being closely coupled live and neutral conductors encountering an electromagnetic field that immerses both conductors equally. For example; a cable picking up transmitted radio energy, from broadcast or wi-fi transmitters for example. The noise has its own current loop and returns through the safety earth conductor via the stray capacitance present in all distributed electrical systems.

ISOL-8-SUBSTATION-TRANS

Both these types of noise are commonly found in the real world. Now let’s look at how to reduce the unwanted noise entering the load. With Common Mode Noise a filter can be readily designed to attenuate the energy down to a given frequency using a common mode inductor. This uses phase cancellation to attenuate unwanted noise. The physical geometry of the inductor produces a relatively large value of inductance, given the core size and number of wire turns. It therefore produces effective filtering but for common noise only. Differential mode noise is able to pass through the filter readily.

ISOL-8-SUBSTATION-TRANS

A different topology is needed to attenuate Differential Mode noise. In this case only separate series inductors in the send (live) and return (neutral) in combination with a shunt capacitor in the current loop can attenuate the noise. Unfortunately the favourable geometry of the common mode inductor is not effective in this case. The series inductors used in the filter must use larger cores and more turns of wire to provide effective attenuation for differential mode noise compared with common mode.

Inferior mains conditioners may claim they filter differential mode noise but in fact use shunt elements without series inductors to divert the noise to earth (known as a Delta configuration). This then pollutes the earth instead, not the optimum solution for sensitive audio equipment as noise is still present on the earth line.

ISOL-8-SUBSTATION-TRANS

ISOL-8 Transmodal Filter: Warning! All mains conditioning is not created equal. Most manufacturers of mains conditioning equipment completely fail to effectively filter differential mode noise as it adds both complexity and cost. ISOL-8 Transmodal filters combat both common and differential modes of transmitted noise whilst keeping the earth clean for maximum filter performance at all times.

ISOL-8-SUBSTATION-TRANS

SubStation E-brosjyre

Les mer her!

Spesifkasjoner

Number of available outlets:4 on LC and Axis
2 on HC
Type of outlets available:13A UK, Schuko, 15A US
Power Input:Neutrik 20A powerCON (cable not supplied)
Dimensions:W: 232mm
H: 135mm
D: 420mm (excluding connectors)
Weight:4.8 Kg (Axis)
5.8 Kg (LC)
10.9 Kg (HC)
Construction:Aluminium chassis with Silver finish
Aluminium alloy panels (Black optional)
Mains Voltage:230VAC version for 220-240VAC
117VAC version for 100-127VAC
Maximum continuous Current:LC 8 Amps across any one power outlet
LC 8 Amps across all outlets
HC and Axis 16Amps across any one power outlet
HC and Axis 16Amps across all outlets
Protection:Rear panel circuit breaker